BKPDZ - PM SOLVENT

  • MSDS: BKPDZ
  • Manufacturer: ARCO CHEMICAL CO
  • Product Name: PM SOLVENT
  • National Stock Number: 6810-00N014788
Product Identification

Product ID:PM SOLVENT
MSDS Date:01/30/1989
FSC:6810
NIIN:00N014788
MSDS Number: BKPDZ

Responsible Party
ARCO CHEMICAL CO
3801 WEST CHESTER PIKE
NEWTON SQUARE, PA 19073
US

Emergency Phone: 215-353-8300;800-424-9300(CHEMTREC)

Info Phone: 800-321-7000

Cage: ARCOC

Contractor
ARCO CHEMICAL CO
NEWTON SQUARE, PA 19073 US

Telephone: 800-321-7000

Cage: ARCOC

Ingredients

POISONING RISK. GET MD. TREAT SYMPTOMATICALLY.

RTECS: 9999999ZZ


IMPOUND AND RECOVER LARGE LAND SPILL. SOAK UP

RTECS: 9999999ZZ


ON WATER, MATL SOLUBLE/FLOATS. CONTAM/MINIMIZE

RTECS: 9999999ZZ


HARM. REPORT PER REGULATORY REQUIREMENTS.

RTECS: 9999999ZZ


W/APPLIC REGS. DILUTED AQ WASTE MAY

RTECS: 9999999ZZ


ASSURE EFFLUENT COMPLIES WITH APPLICABLE

RTECS: 9999999ZZ


STEEL TO AVOID SLIGHT DISCOLORATION FROM MILD

RTECS: 9999999ZZ


ASSN. STD.) SHOWED NO CORROSION AFTER 30 DAY CNTCT

RTECS: 9999999ZZ


ETHERS/ETHER ESTERS. THIS PROD WILL ABSORB WATER IF

RTECS: 9999999ZZ


SYSTEMS/EQUIP BEFORE MAINT/REPAIR. REMOVE ALL

RTECS: 9999999ZZ


OXYGEN DEFICIENCIES. USE ADEQUATE PERSONAL PROT

RTECS: 9999999ZZ


AND WASH THOROUGHLY BEFORE REUSE. SHOWER

RTECS: 9999999ZZ


WORK PRACTICES ARE NEEDED BEYOND THE ABOVE

RTECS: 9999999ZZ


PROPYLENE GLYCOL MONOMETHYL ETHER

CAS: 107-98-2

RTECS: UB7700000

Fraction By Weight: 98-100%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192


2-METHOXY-1-PROPANOL

CAS: 1589-47-5

Fraction By Weight: 2%


HEAVIER THAN AIR. MAY TRAVEL LONG DISTANCES

RTECS: 9999999ZZ


SOURCE. DILUTING WITH WATER MAY NOT SUFFICE TO

RTECS: 9999999ZZ


LABORATORY ANIMALS (RATS/MICE) & MAY HAVE

RTECS: 9999999ZZ


IF VICTIM COMPLETELY CONSCIOUS/ALERT. DO

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: PRLNG OVEREXP MAY CAUSE
COUGHING, SHORTNESS OF BREATH, DIZZ & INTOXICATION. EYES: MAY CAUSE
MINOR EYE IRRITATION. SKIN: EXTENSIVE/PRLNG OR RPTD EXPOS TO MATL
CAN RSLT IN SIGNIFICANT ABSO RPTION. INGEST: MATL MAY BE A SLIGHT
HLTH HAZ IF INGESTED IN LARGE QTYS. CHRONIC: RATS EXPOSED TO (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE
Effects of Overexposure:HLTH HAZ: ATMOSPHERIC CONCENTRATIONS OF
PROPYLENE GLYCOL MONOMETHYL ETHER (ARCOSOLV PM) FOR 3 MONTHS SHOWED
ONLY MINIMAL TOXICITY AT THE HIGH DOSE LEVEL OF 3000 PPM. NO
STUDIES OF LONGER DURATION HAVE BEEN CONDUCTED AT THIS TIME. NIOSH
STUDIES INDICATE 1-METHOXY-2-PROPANOL HAS CAUSED REPRO DISORDERS IN
(SEE INGRED 05)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR IMMED. GIVE O*2/ARTF RESP AS
NEEDED. GET MD IMMED. EYES: IMMED RINSE W/CLEAN WATER FOR 20-30
MIN. RETRACT EYELIDS OFTEN. GET MD IF PAIN, BLINKING, TEARS OR
REDNESS PERSIST. SKIN: REMOVE CONTAM CLTHG AS NEEDED. WASH THORO
W/MILD SOAP/WATER. FLUSH W/LUKEWARM WATER FOR 15 MIN. IF STICKY,
USE WATERLESS CLEANER FIRST. INGEST: LG QTY: GIVE LUKEWARM WATER
(PINT) (SEE INGRED 06)

Fire Fighting

Flash Point Method:TCC
Flash Point:89.0F,31.7C
Lower Limits: 3%
Upper Limits: 12%
Extinguishing Media:DRY CHEMICAL, CO*2, WATERSPRAY, ALCOHOL TYPE FOAM,
WATER FOG.
Fire Fighting Procedures:DO NOT ENTER FIRE AREA W/O PROPER PROT. WEAR
NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . FIGHT FIRE FROM SAFE
DISTANCE/PROTECTED LOCATION. (SEE SUPP DATA)
Unusual Fire/Explosion Hazard:RELEASE VAPS @ NORMAL AMBIENT TEMPS. WHEN
MIXED W/AIR & EXPOSED TO IGNIT SOURCE, VAPS CAN BURN IN OPEN OR
EXPLODE IF CONFINED. FLAMM VAPS MAY BE (SEE INGRED 03)

Accidental Release

Spill Release Procedures:FLAMM LIQ. REL CAN CAUSE FIRE/EXPLO. LIQS/VAPS
MAY IGNITE. EVAC/LIMIT ACCESS. EQUIP RESPONDERS W/PROPER PROT. STOP
REL. EXTING ALL IGNIT SOURCES. NOTIFY FIRE/ENVIRON AUTH. BLANKET
W/FIRE FIGHT FOAM. P VNT FLOW TO SEWERS/PUBLIC WATERS. (SEE INGRED
08)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE ONLY IN TIGHTLY CLOSED/PROPERLY
VENTED CNTNRS AWAY FROM HEAT/SPARKS/OPEN FLAME/STRONG OXIDIZING
AGENTS. USE ONLY NON-SPARKING (SEE OTHER PREC)
Other Precautions:HNDLG/STOR PREC: TOOLS. GROUND CNTNRS BEFORE
BEGINNING TRANSFER. ELEC EQUIP SHOULD CONFORM TO NATL ELEC CODE.
HNDL EMPTY CNTNRS CAREFULLY. FLAMM/COMBUST RESIDUE REMAINS AFTER
EMPTYING. STORE IN PROPER LY LINED STEEL/STAINLESS (SEE INGRED 13)

Exposure Controls

Respiratory Protection:IF EXPOSURE EXCEEDS PEL/TLV, USE ONLY NIOSH/MSHA
APPRVD AIR-PURIFYING OR SUPPLIED AIR RESP OPERATED IN POS PRESS
MODE.
Ventilation:GENERAL ROOM OR LOCAL EXHAUST VENTILATION.
Protective Gloves:PROTECTIVE GLOVES
Eye Protection:CHEM WORK GOGGLES /FACESHLD OPTNL.
Other Protective Equipment:DEPENDING ON CONDITIONS OF USE, PROTECTIVE
APRON, BOOTS, AND HEAD PROTECTION SHOULD BE WORN. CLEAN THORO AFTER
EACH USE.
Work Hygienic Practices:WASH HANDS BEFORE EATING, DRINKING, SMOKING, OR
USING TOILET FACILITIES. PROMPTLY REMOVE SOILED CLOTHING (SEE
INGRED 18)
Supplemental Safety and Health
FIRE FIGHT PROC: HEAT MAY BUILD PRESS/RUPTURE CLOSED CNTNRS, SPREADING
FIRE, INCREASING RISK OF BURNS/INJURIES. WATER MAY BE INEFTIVE IN
FIREFIGHTING DUE TO LOW FP. USE WATER SPRAY/FOG FOR COOLING. EV EN
IF WATER SOL, MAY NOT BE PRACTICAL TO EXTING FIRE BY WATER
DILUTION. NOTIFY AUTH IF LIQ ENTERS SEWER/PUBLIC WATERS.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:243F,117C
Melt/Freeze Pt:M.P/F.P Text:-139F,-95C
Vapor Pres:10.9 @ 77F
Spec Gravity:0.92
Evaporation Rate & Reference: 0.7 (BUTYL ACETATE = 1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID; ETHEREAL ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS; EXTENDED CONTACT WITH AIR OR OXYGEN.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME; STRONG OXIDIZING
CONDITIONS.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION WILL GENERATE
HIGHLY POISONOUS CO AND PERHAPS OTHER TOXIC VAPORS.

Disposal

Waste Disposal Methods:CONTAM PROD/SOIL/WATER MAY BE RCRA/OSHA HAZ
WASTE DUE TO POTENTIALLY LOW FP. LANDFILL SOLIDS @ PERMITTED SITES.
USE REGISTERED TRANSPORTERS. BURN CONC LIQS IN SYS COMPAT W/WATER
SOL WASTES. AVOID FLAM EOUTS. ASSURE EMISSIONS COMPLY (SEE INGRED
11)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.